OPERATING PRINCIPLE
The KENCO LCP utilizes the operating principles of both the oil level
controller and the electric switch.
APPLICATIONS
Remote or offshore locations with no electric
power.
STANDARD MATERIALS OF CONSTRUCTION
- Valve Seat - Nitrile
- Optional Valve Seat Material - Fluorocarbon
- Valve Orifice - Aluminum
- Housing - Aluminum
- Float Material - Closed Cell Polyurethane
- Oil Inlet Screen - 20 Mesh Brass Cloth
- Sight Window - Clear Polycarbonate (UV Stabilized)
|
OIL INLET SPECIFICATIONS
- Static Head Pressure Range - 1-15 ft.
- High Pressure Models -
- A
- 5-35 psi
- B
- 36-70 psi
|
FLOW RATE TEST RESULTS
Low Pressure Tested at 32 º F with SAE 30
2' head = 1.1413 GPH 4' head = 2.122 GPH 7' head = 2.853
GPH 12' head = 3.043 GPH
|
High Pressure Tested at 20 º F with SAE 30
5 PSI = 0.163 GPH 20 PSI = 0.266
GPH |
PNEUMATIC SWITCH SPECIFICATIONS
- Switch trip point: 3/4" drop
- Maximum Air Valve Inlet Pressure - 100 psi
- Switch Test Button Standard
- Air Inlet Connection: 1/4" FNPT
- Maximum Temperature: 180of / 82oC
|
SHIPPING WEIGHT
6.5 lbs.
|